Vulcan-Hart VCE6H ML-126177 manual The timer will start counting down

Models: VCE6H ML-126177 VCE6H ML-126177, VCE10H ML-126178, VCE10F ML-126179, VCE20H ML-126172, VCE20F ML-126173

1 40
Download 40 pages 15.2 Kb
Page 35
Image 35
The timer will start counting down.

If the cavity temperature is above 212°F, automatic Cool Down will occur. During automatic Cool Down, the Time Display will show the rain symbol instead of time.

The timer will start counting down.

The steam generator will fill with water until the water level controls shut off the fill.

The steam generator heater elements will produce steam for 30 minutes. After 30 minutes, the steam generator tank will drain.

The Time Display will show 10 minutes. The timer will not count down.

The Steam Generator will fill and drain two times. The fill time is programmed for each model.

The Time Display will begin counting down, the Steam Generator heaters are ON with steam being generated.

At the end of the ten minute interval, the Steam Generator tank will drain.

'DONE' will display in the Temperature Display indicating that the Clean Cycle is complete.

NOTE: If an error occurs during the Clean Cycle, 'FAIL' will display in the Temperature Display instead of 'DONE'.

Per the instructions in the filter cartridge replacement and preventive maintenance kit: Retest the water, return the response card and replace the filter cartridge.