How it works . . .
①Control module
The control module responds to signals from the room thermostat, air pressure switch and boiler limit circuit to operate the boiler circulator, pilot burner, gas valve and inducer. When room thermostat calls for heat, the control module starts the system circulator and inducer.
The control module runs the inducer long enough to purge the boiler flue passages, then opens the pilot valve and activates pilot ignition spark.
The control module allows up to 15 seconds to establish pilot flame. If flame is not sensed within 15 seconds, the control module will turn off the gas valve, flash the Flame light, and then enter a
When the room thermostat is satisfied, the control module turns off the gas valve, operates the inducer for a
The control module indicator lights show normal sequence when the lights are on steady. When a problem occurs, the control module flashes combinations of lights to indicate the most likely reason for the problem (see page 49).
②
③
Transformer
The control transformer reduces line voltage to 24 volts for the gas valve and limit circuit.
Inducer
The inducer pulls flue gases through the boiler, causing air to be pulled in through the boiler air openings. The inducer pushes the flue gases through the vent pipe as well.
④Air pressure switch
The air pressure switch signals the control module, telling the control module whether the inducer is working correctly or the vent is blocked.
⑤Water temperature limit switch
The water temperature limit switch turns off the gas valve if the temperature in the boiler goes above its setting. (The circulator will continue to run as long as there is a call for heat.)
⑥Boiler circulator
The boiler circulator circulates water through the external (system) piping. The circulator is shipped loose, and can be mounted on either the boiler supply or return piping. The factory- installed circulator wiring harness provides ample length for either location. NOTE — The control module provides a pump exercising routine. If the boiler is not operated for 30 days, the control module will power the circulator for 30 seconds, then turn off.
Other boiler components:
asupply to system
breturn from system
cstainless steel burners
dflue outlet
egas valve
fpressure/temperature gauge
grelief valve
hair vent connection
iflame rollout thermal fuse element (TFE)
jburner shield
kpilot burner and bracket
lgas manifold
mcast iron boiler sections
nflue collector
ojunction box
Part Number