Command Reference Guide

/C Connect

Establishes a bidirectional connection between two ports. For more information and command line examples, please refer to Section 8.1. There are two types of port connections:

Resident Connect: If the /C command specifies one port name or number, your resident port will be connected to the specified port.

Third Party Connect: If the /C command specifies two port names or numbers, the unit will connect the two ports indicated. A Third Party Connect command must be issued from a third port where Supervisor Mode is active. Passwords and ports that do not permit Supervisor Mode cannot initiate a Third Party Connect.

Note:

Passwords and ports that do not permit Supervisor Mode can only connect to the ports that are specifically allowed by the password entered at log in.

Passwords and ports that permit Supervisor Mode can connect to any free APS-8/16M port.

Availability: Supervisor Mode / Non-Supervisor Mode

Format: /C <x> [x] [Enter]

Where x is the number or name of the port(s) to be connected.

Response:

Verbose: Connected xx, when a Resident Connection is initiated, the APS-8/16M will also display the currently selected Resident Disconnect Sequence for your port.

Terse: 1

/CP Copy RS232 Port Parameters

Allows quick set-up when all RS232 ports will be configured with the same or similar parameters. When the /CP command is invoked, the APS-8/16M will display a menu that is used to select common port parameters, which can then be copied to all APS-8/16M RS232 ports. Note that the Copy Command will not change restricted parameters at Ports 1 and 2 or the Internal Modem Port. For more information, please refer to Section 5.6.

Availability: Supervisor Mode Only

Format: /CP [Enter]

Response: Displays Copy Parameters Menu

11-5

Page 65
Image 65
Western Telematic APS-16M, APS-8M manual Format /C x x Enter, Format /CP Enter, 11-5