| Hardware Installation |
4.3.5. Default ARQ/Compression Status (Sw6)
SetUp Switch six selects the default enabled/disabled status for the ARQ/Compression feature. The ARQ mode and compression feature can also be enabled or disabled via the Modem Parameters menu (/M). If the
Default ARQ / Compression Status | Sw6 |
Enable * | Down |
Disable | Up |
*= Factory Setting
4.3.6.Default Modem Speaker Status (Sw7)
SetUp Switch seven selects the default enabled/disabled status for the modem speaker. The Modem Parameters menu (/M) can also be used to enable/disable the speaker. If the SRM is reinitialized, this feature will return to the setting selected by SetUp Switch seven.
Default Modem Speaker Status | Sw7 |
On * | Down |
|
|
Off | Up |
*= Factory Setting
4.3.7.Default Security Mode Status (Sw8)
SetUp Switch eight selects the default enabled/disabled status for the Security Mode. The Security Mode can also be disabled via the General Parameters Menu (/G). If the unit is reinitialized, the Security Mode will return to the default status selected by SetUp Switch eight.
Note: If Modem Security is disabled (off), all password and security features will be suppressed, and you will not be able to access the SRM command mode via modem (although Console Port access to command mode is still allowed). When the Security Mode is disabled, the SRM will function like a normal
Security Mode | Sw8 |
On * | Down |
|
|
Off | Up |
* = Factory Setting