DIAGNOSTIC TEST

The control must be in the OFF state before pressing the touch-pad sequence to start the test.

Starting the test mode

Close the door.

Press the Control On button. Select the DRAIN/SPIN cycle.

Select NO SPIN by pressing the SPIN SELECT button, as needed.

Push Prewash Option button four (4) times within five (5) seconds. C:00 will show in the display. NOTE: If Model does not have PREWASH Mode as an option, press RINSE/HOLD.

If the Starting procedure fails, push PAUSE/CANCEL button. Then repeat the starting sequence.

Test Program Control during Execution

To advance to the next step of the test procedure, push Prewash Option button two (2) times.

Overview Test Program

Indication

Control Action

Actuators to be Checked

C:00

Door is Locked

Door Lock System

 

 

 

C:01

Filling by cold water inlet valve

Flowmeter, Cold water inlet valve

 

 

 

C:02

Distribution system is set to Prewash position

Dispenser motor,

 

 

Dispenser contact

 

 

 

C:03

Fill by hot water inlet valve

Hot water inlet valve

 

 

 

C:04

Basket rotates clockwise at wash speed

Motor, MCU control

 

 

 

C:05

Heater is switched ON.

Heater, Temperature Sensor

 

Basket rotates clockwise with wash speed.

 

 

If there is not enough water in the tub, the

 

 

water inlet valve will be switched ON to fill-in

 

 

the minimum water quantity.

 

 

NOTE: On GHW 9100 Models only the

 

 

Temperature Sensor will be checked

 

 

 

 

C:06

Drain Pump is ON

Drain Pump

 

 

 

C:07

Basket rotates counterclockwise

Motor, MCU control

 

from 35 to 90 rpm

 

 

within 15 seconds

 

 

 

 

C:08

Basket rotates counterclockwise

Motor, MCU control

 

with max. speed

 

 

Basket speed > 1100 rpm

 

 

 

 

6 - 8

Page 52
Image 52
Whirlpool GHW9200L Diagnostic Test, Starting the test mode, Test Program Control during Execution, Overview Test Program