50

NUTATE AND RECIRCULATE TEST
This test sequence assu mes the control is off. T he test will timeout aft er 3 minutes of use.
PRESS TOUCHPAD DISPLAY CONTROL ACTION
1 SOAK Key Dance key press #1
2 CYCLE SIGNAL Key Dance key press #2
3 SOAK Key Dance key press #3
4CYCLE SIGNAL Key Dance key press #4
Presses #1 - #4 must be completed in 5 seconds or the key
dance is not valid.
5WATER TEMP Key press #5, “00” on t he display
6WATER TEMP Cold Water Inlet Valve and Fabric Softener disp enser valve
on. Cold/Cold and Norm al (above SOIL LEVEL) LEDs will
turn on.
7 SOIL LEVEL Normal LED will turn off and Heavy LED will turn on. Fabric
softener valve will shut off and Fres h wat er valve will turn on.
8WATER TEMP Cold/Cold LED turns off and Hot/Col d LED tur ns on. Cold
inlet valve turns off and Hot inlet valve tur ns on.
9WATER TEMP Both hot and cold inlet valves turn on.
10 None Wait about 10 seconds un til en ough water is in tub.
11 WATER TEMP All valves turn off.
12 WHITEST WHITES W hitest Whites LED on Unit is now set to 150 RP M nutate speed. Motor doesn’t start
until START is pressed.
13 START Wash LED flashes, then
Rinse LED turns on Wash plate begins nutating at 150 RPM .
14 HEAVY DUTY,
NORMAL,
JEANS/DARKS,
BULKY ITEMS
Wash LED flashes, then
Rinse LED turns on These keys can increase t he nutate speed if nec essary
(optional).
15 EXTEND SPIN Extend Spin LED on Pump s hould turn on in recircul ate mode. Press EXTEN D
SPIN again to turn off pump.
16 STOP/CANCEL All LEDs Off Cancel all diagnostics, go back t o Of f mode. Y ou m ay wan t
to spin and drain out the water in the unit after t h is test.
Pump Drain/Recirculation

4. Press the EXTRA RINSE keypad to operate the pump motor in Drain. Press the EXTEND SPIN

keypad to run the pump motor in Recirculation. Pressing these keypads a second time turns the pump

motor off.