Pump Drain/Recirculation
4.Press the EXTRA RINSE keypad to operate the pump motor in Drain. Press the EXTEND SPIN keypad to run the pump motor in Recirculation. Pressing these keypads a second time turns the pump motor off.
NUTATE AND RECIRCULATE TEST
This test sequence assumes the control is off. The test will timeout after 3 minutes of use.
1
2
3
4
5
6
7
8
9
PRESS TOUCHPAD | DISPLAY | CONTROL ACTION |
SOAK |
| Key Dance key press #1 |
CYCLE SIGNAL |
| Key Dance key press #2 |
SOAK |
| Key Dance key press #3 |
CYCLE SIGNAL |
| Key Dance key press #4 |
|
| Presses #1 - #4 must be completed in 5 seconds or the key |
|
| dance is not valid. |
WATER TEMP |
| Key press #5, “00” on the display |
WATER TEMP |
| Cold Water Inlet Valve and Fabric Softener dispenser valve |
|
| on. Cold/Cold and Normal (above SOIL LEVEL) LEDs will |
|
| turn on. |
SOIL LEVEL |
| Normal LED will turn off and Heavy LED will turn on. Fabric |
|
| softener valve will shut off and Fresh water valve will turn on. |
WATER TEMP |
| Cold/Cold LED turns off and Hot/Cold LED turns on. Cold |
|
| inlet valve turns off and Hot inlet valve turns on. |
WATER TEMP |
| Both hot and cold inlet valves turn on. |
10 | None |
|
|
|
|
|
|
| Wait about 10 seconds until enough water is in tub. |
11 | WATER TEMP |
|
|
|
|
|
|
| All valves turn off. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
12 | WHITEST WHITES | Whitest Whites LED on | Unit is now set to 150 RPM nutate speed. Motor doesn’t start | ||||||
|
|
|
|
|
|
|
|
| until START is pressed. |
13 | START | Wash LED flashes, then | Wash plate begins nutating at 150 RPM. | ||||||
|
| Rinse LED turns on |
| ||||||
|
|
|
| ||||||
14 | HEAVY DUTY, | Wash LED flashes, then | These keys can increase the nutate speed if necessary | ||||||
| NORMAL, | Rinse LED turns on | (optional). | ||||||
| JEANS/DARKS, |
|
|
|
|
|
|
|
|
| BULKY ITEMS |
|
|
|
|
|
|
|
|
15 | EXTEND SPIN | Extend Spin LED on | Pump should turn on in recirculate mode. Press EXTEND | ||||||
|
|
|
|
|
|
|
|
| SPIN again to turn off pump. |
16 | STOP/CANCEL | All LEDs Off | Cancel all diagnostics, go back to Off mode. You may want | ||||||
|
|
|
|
|
|
|
|
| to spin and drain out the water in the unit after this test. |
50