Windsor 30 SP Maintenance and care, Faults, Transport, Maintenance schedule, Maintenance Works

Models: 30 SP 30

1 53
Download 53 pages 30.32 Kb
Page 12
Image 12
Drain off clean water

ÎLet off dirty water by opening the dos- age device at the discharge hose.

ÎRinse the dirty water tank with clear wa- ter.

Drain off clean water

ÎRemove the suction hose coupling for draining off the fresh water and hold it over a suitable container.

Transport

￿Danger

Risk of injury! When loading or unloading the machine, it may only be operated on gradients of max. 10%. Drive slowly.

ÎIf you want to transport the machine on a vehicle secure it from slipping using belts/ ropes.

Saber Glide 30

ÎRemove brushes from the brush head.

Maintenance and care

￿Danger

Risk of injury! Before carrying out any tasks on the machine, set the main key to "0" and remove it. Pull out the battery plug.

Note

Suction turbine will continue to run for a while after switch-off. Carry out mainte- nance tasks only after the suction turbine has come to a halt.

ÎDrain and dispose of the dirty water and the residual fresh water.

Maintenance schedule

After each operation

￿Warning

Risk of damage. Do not wash down the ap- pliance with water and do not use aggres- sive detergents.

ÎDrain off dirty water.

ÎRinse the dirty water tank with clear wa- ter.

12English

ÎCheck the lint filter, clean if required

ÎOnly SP model: Remove bulk waste container and empty it.

ÎClean the outside of the appliance with a damp cloth which has been soaked in mild detergent.

ÎClean the squeegee blades and the wiping lips, check for wear and replace if required.

ÎCheck the brushes for wear, replace if required.

ÎCharge battery.

Monthly

ÎCheck battery pole for oxidation; brush it if required and lubricate it using pole grease. Ensure that the connection ca- ble sits firmly.

ÎClean the seals between dirty water res- ervoir and cover and check for tight- ness, replace if required.

ÎCheck the function of the immobilizing brake.

ÎCheck the acid density of the cells if the batteries are not maintenance-free bat- teries.

ÎClean the brush tunnel (only SP model).

Yearly

ÎHave the prescribed inspection carried out by the customer service.

Maintenance Works

Maintenance contract

To ensure a reliable operation of the appli- ance maintenance contracts can be con- cluded with the competent Windsor sales office.

Replacing the squeegee blades

ÎRemove the squeegee tool.

ÎLoosen knobs-handles.

ÎRemove the plastic parts.

ÎRemove the squeegee blades.

ÎInsert new squeegee blades.

ÎInsert the plastic parts.

ÎTighten the cross-handles.

Replacing the brush rollers

ÎRelease the wing nuts.

ÎRemove bearing lid.

ÎTake out the brush roller, insert a new one (pay attention to the hexagonal in- take of the brush rollers).

ÎPlace bearing lid.

ÎTighten the wing nuts.

ÎRepeat process on the opposite side.

Replacing the Disk Brushes

ÎRaise the disk brushes.

ÎTurn the disk brushes by approximately 45°.

ÎRemove the disk brushes at the bottom.

ÎInsert the new disk brushes in reverse sequence.

Frost protection

In case of danger of frost:

ÎEmpty the fresh and dirty water reser- voirs.

ÎStore the appliance in a frost-protected room.

Faults

￿Danger

Risk of injury! Before carrying out any tasks on the machine, set the main key to "0" and remove it. Pull out the battery plug.

ÎDrain and dispose of the dirty water and the residual fresh water.

In case of faults that cannot be remedied using the table below please contact the customer service.

Replace fuses

The operator may only replace the following vehicle flat fuses having the following val- ues:

7.5A (F1) – Control and emergency power supply.

30A (F4) – Supply to stroke and acces- sories module.

Note

Defective fuses (F2, f3) should only be re- placed by the service center. If these fuses are defective, then customer service center has to check the usage conditions and the

Page 12
Image 12
Windsor 30 SP Maintenance and care, Faults, Transport, Maintenance schedule, Maintenance Works, Frost protection, Monthly