Table 1-2. System Messages (continued)
Message | Causes | Corrective Actions |
Warning: A fatal | A fatal system error |
error has caused | occurred and caused |
system reset! | the system to reboot. |
Please check the |
|
system event log! |
|
Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 129 for any faulty components specified in the SEL.
Warning: | Control | The control panel is not |
Panel is | not | installed or has a faulty |
installed. | cable connection. |
Install the control panel, or check the cable connections between the display module, the control panel board, and the system board. See "Control Panel Assembly" on page 120.
Warning! No micro Micro code update failed. | Update the BIOS firmware. |
code update | See "Getting Help" on |
loaded for | page 157. |
processor n |
|
Warning! Power | The system configuration of |
required exceeds | processor, memory modules, |
PSU wattage. | and expansion cards may |
Check PSU and | not be supported by the |
system | power supply. |
configuration. |
|
Warning! |
|
Performance |
|
degraded. CPU and |
|
memory set to |
|
minimum |
|
frequencies to |
|
meet PSU wattage. |
|
System will |
|
reboot. |
|
If any system components were just upgraded, return the system to the previous configuration.
If the system boots without this warning, then the replaced component(s) are not supported with this power supply. See "Chassis Intrusion Switch" on page 118.
About Your System