Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

The following

Invalid memory

DIMMs should

configuration. The specified

match in

memory modules do not

geometry:

match in size, number

x,x,...

of ranks, or number of

The following

data lanes.

 

DIMMs should

 

match in rank

 

count: x,x,...

 

Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 98.

The following DIMMs should match in size: x,x,...

The following DIMMs should match in size

and geometry:

x,x,...

The following DIMMs should match in size and rank count:

x,x,...

Thermal sensor

A memory module without a

Replace the memory module.

not detected on x thermal sensor is installed in

See "Expansion Cards" on

 

the specified memory slot

page 103.

 

 

 

Time-of-day

Faulty battery or faulty chip.

See "Troubleshooting the

clock stopped

 

System Battery" on page 134.