NOTE: The following LCD status messages are displayed in the Simple format.

Table 1-1. LCD Status Messages

Code

Text

Causes

Corrective Actions

E1000 Failsafe voltage error. Contact support.

Check the system event log for critical failure events.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 157.

E1114 Ambient Temp

Ambient temperature has

See "Troubleshooting

exceeds

reached a point outside of

System Cooling Problems"

allowed

the allowed range.

on page 136.

range.

 

 

E1116 Memory

Memory has exceeded

disabled,

allowable temperature

temp above

and has been disabled

range. Power

to prevent damage to

cycle AC.

the components.

Remove AC power to the system for 10 seconds and restart the system.

See "Troubleshooting System Cooling Problems" on page 136. If the problem persists, see "Getting Help" on page 157.

E1210

Motherboard

CMOS battery is missing

See "Troubleshooting the

 

battery

or the voltage is outside

System Battery" on

 

failure.

of the allowable range.

page 134.

 

Check

 

 

 

battery.

 

 

E1216

3.3V

3.3V voltage regulator

Remove and reseat the

 

Regulator

has failed.

PCIe expansion cards.

 

failure.

 

If the problem persists,

 

Reseat PCIe

 

see "Troubleshooting

 

cards.

 

Expansion Cards" on

 

 

 

page 143.

24

About Your System

Page 24
Image 24
Dell NX200 owner manual LCD Status Messages Code Text Causes Corrective Actions