Dell NX200 owner manual

Models: NX200

1 166
Download 166 pages 12.85 Kb
Page 30
Image 30

Table 1-1. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1717

CPU #

The system BIOS has

Check the SEL for

 

internal

determined that the

more information, and

 

error. Review

processor has had an

then clear the SEL.

 

& clear SEL.

internal error.

Remove AC power to the

 

 

 

system for 10 seconds,

 

 

 

and restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 157.

 

 

 

 

E171F

PCIe fatal

The system BIOS has

Remove and reseat the

 

error on Bus

reported a PCIe fatal error

PCIe expansion cards.

 

## Device ##

on a component that

If the problem persists,

 

Function ##

resides in PCI

see "Troubleshooting

 

 

configuration space at

Expansion Cards" on

 

 

bus ##, device ##,

page 143.

 

 

function ##.

 

 

 

 

 

E1810

Hard drive ##

The specified hard drive

See "Troubleshooting a

 

fault. Review

has experienced a fault.

Hard Drive" on page 141.

 

& clear SEL.

 

 

E1812

Hard drive ##

The specified hard drive

Information only.

 

removed.

has been removed from

 

 

Check drive.

the system.

 

E1A1D Control panel

USB cable to the

USB cable not

control panel is

detected.

missing or bad.

Check cable.

 

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 157.

E2010 Memory not

No memory was

Install memory or reseat

detected.

detected in the system.

the memory modules.

Inspect

 

See "Installing Memory

DIMMs.

 

Modules" on page 100 or

 

 

"Troubleshooting System

 

 

Memory" on page 137.

30

About Your System

Page 30
Image 30