Dell NX200 owner manual Faulty system board See Getting Help on

Models: NX200

1 166
Download 166 pages 12.85 Kb
Page 43
Image 43

Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

No boot sector on Incorrect configuration

hard drive settings in System Setup program, or no operating system on hard drive.

Check the hard-drive configuration settings in the System Setup program.

See "Using the System Setup Program and UEFI Boot Manager" on page 51.

If necessary, install the operating system on your hard drive. See your operating system documentation.

No timer tick

Faulty system board.

See "Getting Help" on

interrupt

 

page 157.

PCI BIOS failed

PCIe device BIOS (Option

Reseat the expansion card(s).

to install

ROM) checksum failure

Ensure that all appropriate

 

detected during shadowing.

cables are securely connected

 

Cables to expansion card(s)

to the expansion card(s).

 

If the problem persists,

 

loose; faulty or improperly

 

see "Troubleshooting

 

installed expansion card(s).

 

Expansion Cards" on

 

 

 

 

page 143.

PCIe Training Error: Expected Link Width is x, Actual Link Width is y.

Faulty or improperly installed PCIe card in the specified slot.

Reseat the PCIe card in the specified slot number.

See "Troubleshooting Expansion Cards" on page 143. If the problem persists, see "Getting Help" on page 157.

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration

initializing PCIe device;

jumper in the clear position

Error

faulty system board.

(pins 1 and 3) and reboot the

 

 

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists,

 

 

see "Troubleshooting

 

 

Expansion Cards" on

 

 

page 143.

About Your System

43

Page 43
Image 43
Dell NX200 owner manual Faulty system board See Getting Help on