Table 1-1. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

E1712 PCI system

The system BIOS has

error on Bus

reported a PCI system

##Device ## error on a component

Function ## that resides in PCI configuration space at bus ##, device ##, function ##.

Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 143.

E1714

Unknown

The system BIOS has

Check the SEL for more

 

error. Review

determined there has

information and then

 

& clear SEL.

been an error in the

clear the SEL.

 

 

system, but is unable to

Remove AC power to the

 

 

determine its origin.

system for 10 seconds and

 

 

 

restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 157.

 

 

 

 

E1715

Fatal I/O

The system BIOS has

Check the SEL for

 

Error. Review

determined there

more information,

 

& clear SEL.

has been a fatal error

and then clear the SEL.

 

 

in the system.

Remove AC power to the

 

 

 

system for 10 seconds,

 

 

 

and restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 157.

 

 

 

 

E1716

Chipset IERR

The system BIOS has

Check the SEL for

 

Bus ## Dev ##

reported a chipset

more information, and

 

Function ##.

internal error that resides

then clear the SEL.

 

Review &

in bus ##, device ##,

Remove AC power to the

 

clear SEL.

function ##.

system for 10 seconds,

 

 

 

and restart the system.

If the problem persists, see "Getting Help" on page 157.

About Your System

29

Page 29
Image 29
Dell NX200 owner manual Reported a PCI system