Table 1-1. LCD Status Messages (continued)
Code | Text | Causes | Corrective Actions |
I1911 LCD Log Full. LCD overflow message. Check SEL to A maximum of ten error review all messages can be displayed
Errors. sequentially on the LCD. The eleventh message instructs the user to check the SEL for details on the events.
Check the SEL for details on the events.
Remove AC power to the system for 10 seconds or clear the SEL.
I1912 | SEL full. | The SEL is full of | Check the SEL for more |
| Review & | events and is unable to | information and then clear |
| clear log. | log any more. | the SEL. |
W1627 | Power | The system configuration | Turn off power to the |
| required | requires more power than | system, reduce the |
| > PSU | what the power supply can | hardware configuration or |
| wattage. | provide. | install |
| Check PSU and |
| power supply, and then |
| config. |
| restart the system. |
W1628 | Performance | The system configuration | Turn off power to the |
| degraded. | requires more power than | system, reduce the |
| Check PSU and | what the power supply | hardware configuration or |
| system | can provide, but it can | install |
| configur- | boot if throttled. | power supply, and then |
| ation. |
| restart the system. |
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals.
About Your System
35