Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

Memory set to

The memory frequency

minimum

may be intentionally set

frequency.

lower for power conservation.

 

The current memory

 

configuration may

 

support only the

 

minimum frequency.

If not an intentional setting, check any other system messages for possible causes.

Ensure that your memory configuration supports the higher frequency.

See "General Memory

Module Installation Guidelines" on page 98.

Memory tests

 

POST memory test was

Information only.

terminated by

 

terminated by pressing the

 

keystroke.

 

spacebar.

 

MEMTEST lane

 

Invalid memory

Ensure that the memory

failure

 

configuration. A mismatched

modules are installed in

detected on

x

memory module is installed.

a valid configuration.

 

See "General Memory

 

 

 

 

 

 

Module Installation

 

 

 

Guidelines" on page 98.

No boot device

Faulty or missing optical

available

drive subsystem, hard drive,

 

or hard-drive subsystem, or

 

no bootable USB key

 

installed.

Use a bootable USB key, CD, or hard drive. If the problem persists,

see "Troubleshooting an Internal USB Key" on page 139, "Troubleshooting a USB Device" on page 130, "Troubleshooting an Optical Drive" on page 140, and "Troubleshooting a Hard Drive" on page 141.

See "Using the System Setup Program and UEFI Boot Manager" on page 51 for information on setting the order of boot devices.