Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Time-of-day not

Incorrect Time or

Check the Time and Date

set - please run

Date settings;

settings. See "Using the

SETUP program

faulty system battery.

System Setup Program and

 

 

UEFI Boot Manager" on

 

 

page 51. If the problem

 

 

persists, replace the system

 

 

battery. See "Chassis

 

 

Intrusion Switch" on

 

 

page 118.

 

 

 

Timer chip

Faulty system board.

See "Getting Help" on

counter 2 failed

 

page 157.

TPM

A TPM configuration

Information only.

configuration

command has been entered.

 

operation

The system will reboot and

 

honored. System

execute the command.

 

will now reset.

 

 

TPM

This message is displayed

Enter I or M to proceed.

configuration

during system restart after a

 

operation is

TPM configuration

 

pending. Press

command has been entered.

 

(I)to Ignore OR User interaction is required

(M) to Modify to

to proceed.

 

allow this change

 

 

and reset the

 

 

system.

 

 

WARNING:

 

 

Modifying could

 

 

prevent

 

 

security.

 

 

TPM failure

A Trusted Platform Module

See "Getting Help" on

 

(TPM) function has failed.

page 157.

About Your System

47

Page 47
Image 47
Dell NX200 owner manual Incorrect Time or Check the Time and Date