Dell NX200 owner manual Specified power supplys Check the AC power

Models: NX200

1 166
Download 166 pages 12.85 Kb
Page 28
Image 28

Table 1-1. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1620

Power Supply

Specified power supply's

Check the AC power

 

# (### W) AC

AC input is outside of

source for the specified

 

power error.

the allowable range.

power supply. If the

 

Check PSU

 

problem persists,

 

cables.

 

see "Troubleshooting the

 

 

 

Power Supply" on page 135.

 

 

 

 

E1629

Power

The system configuration

Turn off power to the

 

required >

requires more power

system, reduce the

 

PSU wattage.

than the power supply can

hardware configuration or

 

Check PSU and

provide, even with

install higher-wattage

 

config.

throttling.

power supply, and then

 

 

 

restart the system.

 

 

 

 

E1710

I/O channel

The system BIOS has

Check the SEL for more

 

check error.

reported an I/O channel

information and then

 

Review &

check.

clear the SEL.

 

clear SEL.

 

Remove AC power to

 

 

 

the system for 10 seconds

 

 

 

and restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 157.

 

 

 

 

E1711

PCI parity

The system BIOS has

Remove and reseat the

 

error on Bus

reported a PCI parity error

PCIe expansion cards.

 

## Device ##

on a component that

If the problem persists,

 

Function ##

resides in PCI

see "Troubleshooting

 

 

configuration space at

Expansion Cards" on

 

 

bus ##, device ##,

page 143.

 

 

function ##.

 

PCI parity The system BIOS has error on Slot reported a PCI parity error

#.Review & on a component that clear SEL. resides in the specified slot.

Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 143.

28

About Your System

Page 28
Image 28
Dell NX200 owner manual Specified power supplys Check the AC power