6.Command Specification

LOG SENSE

The following parameter codes are supported for each Error Counters Page:

Table 6-17: Error Counter parameter codes

Parameter

Description

Parameter

Default

Default

Code

 

Length (Bytes)

Cumulative

Threshold

0003h

Total Errors Corrected (Soft Errors)

4

0

FFFFFFFFh

0004h

Total Times Correction

4

0

FFFFFFFFh

0005h

Total Groups Processed (Algorithm

4

0

FFFFFFFFh

 

Processed)

 

 

 

0006h

Total Errors Uncorrected (Hard Errors)

4

0

FFFFFFFFh

6.6.5. Last N Error Events List

This page is used to report information on soft and hard errors encountered by the device during normal operation. Each parameter corresponds to an encountered error and is a report of what type of error occurred and when it occurred. The format of the page is given below:

Table 6-18: Last N Error Events Page

Bit

7

6

5

4

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

0

Reserved

 

 

Page Code (07h)

 

 

1

 

 

 

Reserved

 

 

 

2

(MSB)

 

 

Page Length (n*14)

 

 

 

3

 

 

 

 

 

 

 

 

(LSB)

4

(MSB)

 

 

Parameter Code

 

 

 

5

 

 

 

 

 

 

 

 

(LSB)

6

DU (0)

DS (1)

TSD (0)

ETC (0)

TMC (00)

 

LBIN (0)

LP (0)

7

 

 

 

Parameter

Length (0Ah)

 

 

 

8

 

 

 

Parameter Value

 

 

 

17

 

 

 

 

 

 

 

 

 

The Parameter Codes supported are 1 through 30 where 30 is the maximum number of entries in the log page. If there are no entries, the command will return the Page Header with the Page Length field set to ZERO.

Each error event record contains diagnostic information for a single error encountered by the device. The parameter codes associated with the error-event records indicate the order in which the errors occurred. A higher parameter code indicates that the error event occurred later in time.

Each parameter entry is 10 bytes long and has the following format:

 

 

Table 6-19: Error Event format

 

 

Byte Offset

Meaning

0

– 4

Result Message (see Diagnostic Clause)

 

5

Unused

6

– 9

Time-stamp (number of 1 minute increments since power-on)

When the log page becomes full, no more entries will be added until the log is cleared (using one of the methods described previously) or a reset occurs. The current cumulative values will be returned regardless of the page control field in the LOG SENSE CDB.

6-18

SONY AIT-3Ex drive SDX-800V series Ver.1.1

Page 76
Image 76
Sony SDX-800V/R manual Last N Error Events List