LOG SENSE

 

 

 

 

 

 

 

 

6.Command Specification

 

 

 

Table 6-31: Read and Write Frame Error Counter Page Parameter format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit

 

7

 

6

5

4

3

 

2

1

 

0

 

 

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

(MSB)

 

 

Parameter Code

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

(LSB)

 

 

2

 

DU

DS

TSD

ETC

 

TMC

LBIN

LP

 

 

 

 

(0b)

(1b)

(0b)

(0b)

 

(00b)

(0b)

(0b)

 

 

3

 

 

 

 

 

Parameter

Length (4)

 

 

 

 

 

4

 

(MSB)

 

 

Parameter Value

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

(LSB)

 

6.6.11. Data Compression Transfer Log Page (Sony Unique)

The page allows the host to monitor the performance of the ALDC compression. The PC field in LOG SENSE determines whether current cumulative, or current/default threshold values are returned. The page has the following format:

Table 6-32: Data Compression Transfer Log Page

Bit

7

6

5

4

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

0

Reserved

 

 

Page Code (39h)

 

 

1

 

 

 

Reserved

 

 

 

2

(MSB)

 

 

Page Length (58h)

 

 

 

3

 

 

 

 

 

 

 

 

(LSB)

4

(MSB)

 

 

Parameter Code (n)

 

 

 

5

 

 

 

 

 

 

 

 

(LSB)

6

DU (0)

DS (1)

TSD (0)

ETC (0)

TMC (00)

 

LBIN (0)

LP (0)

7

 

 

 

Parameter

Length (4)

 

 

 

8

(MSB)

 

 

Parameter Value

 

 

 

11

 

 

 

 

 

 

 

 

(LSB)

Data Compression Log Page Fields:

Supported Parameter Codes in this page and their meanings are as follows:

Code

Description

0001h

Number of entities written

0002h

Number of entities read

0003h

Number of records written

0004h

Number of records read

0005h

Megabytes to data compression

0006h

Megabytes from data compression

0007h

Megabytes to tape

0008h

Megabytes from tape

0009h

Logical entity size

000Ah

Physical entity size

000Bh

Uncompressed entities

Entities Written/Read: The total number of complete entities written to or read from the tape since the last power-on or Clear Log operation.

Records Written/Read: The total number of records (both compressed and uncompressed) written to or read from the tape since the last power-on or Clear Log operation.

SONY AIT-3Ex drive SDX-800V series Ver.1.1

6-29

Page 87
Image 87
Sony SDX-800V Data Compression Transfer Log Page Sony Unique, Data Compression Transfer Log Bit Byte Reserved Code 39h