2.Specification
SONY AIT-3Ex drive SDX-800V series Ver.1.1 2-5

2.2.2. Altitude

Operating 0 to 10,000 feet

2.2.3. Suspended Particulate

Operating Less than 150 microgram/m3
Based Sampling period 24 hours

2.2.4. Vibration

Operating Swept Sine 5 to 500Hz, @0.25G Peak 1 Octave/min.
3 axis, 3 directions
Non-operating Swept Sine 5 to 500Hz, @ 0.5G Peak 1 Octave/min.
3 axis, 3 directions

2.2.5. Shock

Operating No Data Loss
Half Sine
Performance
5 G Peak 3 ms
3 axes, 3 directions
*Interval 10 seconds
Non-operating No Device Damage
Half Sine
90 G Peak 3 ms
(30 G Peak 11 ms)
3 axes, 3 directions
*Interval 10 seconds

2.2.6. Acoustic Noise

The ambient noise level is no greater than 25 dB (A). The sound-meter on (A) scale is located 1m in front of the
center of the drive front panel. (A): A curve weight
Streaming Write/Read 35dB(A)
Insert/Eject 60dB(A)

2.2.7. ESD

ESD
(Front Panel Only, integrated product)
Discharge Voltage
Less than 15kV: No operation failure
Less than 20kV: No drive damage

2.2.8. EMC

EMI/EMS Emissions & Immunity EN55022 (1998)
EN55024 (1998) + A1 (2001) + A2 (2003)

2.2.9. Orientation

The SDX-800V can be installed in three different mounting positions as shown in the figure below. Each position has
a maximum tolerance of ± 10 degrees.