MODE SELECT

6.Command Specification

6.7.9.Delete Partition (33h) (This mode page is NOT supported)

Table 6-48: Delete Partition Page

Bit

7

 

6

5

 

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

0

 

Reserved

 

 

 

 

Page Code (33h)

 

 

1

 

 

 

 

 

Page Length (8)

 

 

 

2

 

 

 

 

Indicated Partition Number

 

 

 

3

 

 

 

 

 

 

Reserved

 

 

 

4

 

 

 

 

 

 

Reserved

 

 

 

5

 

 

 

 

 

 

Reserved

 

 

 

6

 

 

 

 

 

 

Reserved

 

 

 

7

 

 

 

 

 

 

Reserved

 

 

 

8

 

 

 

 

 

 

Reserved

 

 

 

9

 

 

 

 

 

 

Reserved

 

 

 

SDX-800V rewinds the tape to Bottom of Active Partition, after Delete Partition.

Note 1: The Delete Partition Command is available in the AIT mode and only for an AIT mode cassette.

Note 2: The Indicated Partition Number value specifies the partition number above which partitions are to be deleted. Consequently, the value cannot represent the last, open-ended partition on tape. The specified partition itself is converted into an open-ended partition with its data contents preserved.

Note 3: Delete Partition is System area in the Active partition.

Examples:

Case 1;

With the tape already loaded, and with partition 5 active, the Delete Partition command issued with the Indicated partition Number set to 5 (the last partition) will be rejected with CHECK CONDITION (Illegal parameter). See Notes 2 and 3.

Indicated Partition Number

Partition 0 Partition 1 Partition 2 Partition 3 Partition 4 Partition 5

Active Partition

Case 2;

With the tape already loaded, and with partition 4 active, the Delete Partition command issued with the Indicated Partition Number set to 4 will delete partition 5. SDX-800V will change the value of 5 in the Last Partition Number field in the Volume Information in MIC to 4. No tape motion will take place. The new last partition - partition 4 - will become open-ended, spanning up to the EOM.

After the completion of this command, the Unit Attention condition will be set for other Initiators, with ASC/ASCQ set to 2A01, Mode Parameters changed, and Mode Sense Page 11h will show the following: