REWIND

6.Command Specification

6.24.REWIND 01h

Bit

7

6

5

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

0

 

 

 

Operation

Code (01h)

 

 

 

 

1

 

Obsolete

 

 

 

Reserved

 

 

Immed

2

 

 

 

 

Reserved

 

 

 

3

 

 

 

 

Reserved

 

 

 

4

 

 

 

 

Reserved

 

 

 

5

 

 

 

 

Control

 

 

 

REWIND tells the drive to position the media at the beginning of the currently active partition. Before rewinding, the drive writes any buffered data to tape and appends an EOD marker.

Immed: When this bit is set, the drive writes any remaining buffered data followed by an EOD marker to tape. It then returns status to the Host before beginning the actual rewind operation. If the Immediate bit is not set, status will be returned after the rewind has completed.

SONY AIT-3Ex drive SDX-800V series Ver.1.1

6-97

Page 155
Image 155
Sony SDX-800V/R manual Rewind 01h, Obsolete Reserved Immed Control