6.Command Specification

 

 

 

 

 

SPACE

 

 

 

Table 6-99: SPACE CHECK CONDITION results

 

 

 

 

 

 

 

 

 

 

 

 

 

Spacing

Event

 

 

 

Sense Data

 

 

 

 

 

Detected

Valid

Mark

EOM

Sense Key

ASC/ASCQ

Note

 

 

Blocks

File-mark

1

1

0

No Sense

File-mark Detected

a,b

 

 

 

Set-mark

1

1

0

No Sense

Set-mark Detected

a,b,d

 

 

 

EOD

1

0

0

Blank Check

 

b,e

 

 

 

BOT

1

0

1

No Sense

BOM/P Detected

b,f

 

 

 

Phy EOT

1

0

1

Medium Error

EOM/P Detected

b,g

 

 

File-marks

Set-mark

1

1

0

No Sense

Set-mark Detected

a,b,d

 

 

 

EOD

1

0

0

Blank Check

 

b,e

 

 

 

BOT

1

0

1

No Sense

BOM/P Detected

b,f

 

 

 

Phy.EOT

1

0

1

Medium Error

EOM/P Detected

b,g

 

 

Set-marks

EOD

1

0

0

Blank Check

 

b,e

 

 

 

BOT

1

0

1

No Sense

BOM/P Detected

b,f

 

 

 

Phy.EOT

1

0

1

Medium Error

EOM/P Detected

b,g

 

 

EOD

BOT

0

0

1

No Sense

BOM/P Detected

c,f

 

 

 

Phy.EOT

0

0

1

Medium Error

EOM/P Detected

c,g

 

 

 

 

 

 

 

 

 

 

 

Note a: The logical position is located on the EOM side of the mark if movement was in the forward direction and on the BOM side of the mark if movement was in the reverse direction.

Note b: The Information field is set to the difference (residue) between the requested count and the actual number of blocks, file marks, Set-marks, or spaced over.

Note c: The Information field will contain no residue count and therefore the Valid bit is not set.

Note d: The drive will only report that a Set-mark has been detected while spacing over blocks or File marks, if it has been configured through MODE SELECT to Report Set-marks. Otherwise, the drive will continue the space operation and the presence of the Set-mark will be transparent to the Host.

Note e: The tape is positioned such that a subsequent WRITE would append data after the last entity that has been written to the tape before EOD.

Note f: The tape is physically positioned at BOM/P.

Note g: EOM is only reported when the physical EOM/P is encountered. The tape is physically positioned at EOM/P.

6-102

SONY AIT-3Ex drive SDX-800V series Ver.1.1

Page 160
Image 160
Sony SDX-800V/R manual Eom, Sense Key, Asc/Ascq