7.Drive Diagnostics

In SCSI-2 mode, the Page Format (PF) bit is one, and the Parameter List Length is 9, the Parameter List in this case is 9 bytes long and will be of the form:

Table 7-2: SEND DIAGNOSTIC Parameters - SCSI-2

Bit

7

6

5

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

0

 

 

 

Page Code (81h)

 

 

 

1

 

 

 

 

Reserved

 

 

 

2

(MSB)

 

 

Page Length (00 05h)

 

 

 

3

 

 

 

 

 

 

 

 

 

(LSB)

4

 

 

 

Diagnostic Test Number

 

 

 

5

Break

 

 

 

Loop Count Identifier

 

 

 

6

 

 

 

Parameter A

 

 

 

7

 

 

 

Parameter B

 

 

 

8

 

 

 

Parameter C

 

 

 

Break: Indicates how to terminate the loop count should an error occur.

0 = stop on first error

1 = do not stop on error

Loop Count Identifier: The number of times that the test should be repeated before status is returned.

0 = run once

1 = run once

2 = run 10 times

3 = run 100 times

4 = run 1000 times

Parameters A, B, C: Any additional parameters required to fully define the diagnostic test. These parameters are unused and shall be 00h.

7.2.4.Diagnostic Test Number Summary

The following is a list of the diagnostic capabilities of the SDX-800V. The Test Availability Code indicates if a particular test can be executed by the Host computer or is executed during Power-on diagnostics (or both). The drive also supports three types of diagnostics:

1.Individual Tests - Self contained modules designed to test a particular function of drive

2.Sequences - Automatic execution of a series of individual tests

3.Exercisers - Verification of a major function of the drive such as Read, Write, Search, etc.

The Diagnostic Test Number for each Test, Sequence or Exerciser is shown in the first column. Test Availability Codes

PPower–on Self–test H ─ Host Diagnostics PH ─ both

SONY AIT-3Ex drive SDX-800V series Ver.1.1

7-3

Page 171
Image 171
Sony SDX-800V/R manual Diagnostic Test Number Summary, Send Diagnostic Parameters SCSI-2 Bit Byte Code 81h Reserved