6.Command Specification

LOG SENSE

Kilobytes to/from Data Compression: The total number of kilobytes written to or read from the tape since the last power-on or Clear Log operation. For Kilobytes from Data Compression, this number may be greater than the number of kilobytes transferred to the host due to read ahead.

Logical Entity Size: The logical size of the last entity written to or read from the tape: size = number of record in entity record size in bytes

Physical Entity Size: The physical size of the last entity written to or read from the tape: size = entity header length + uncompressed data length

Uncompressed Entities: The total number of times non-ALDC entities have been encountered on the tape during read operations since the last power-on or Clear Log operation.

6.6.12. AIT Log Page (Sony Unique)

This page is for the AIT original Tape Log. The AIT Tape Log of each fields are larger than legacy Tape Log Page. The legacy Tape Log Page returns the part of AIT original. This page indicated the Partition Information at the current Partition.

Table 6-33: AIT Log Page

Bit

7

6

5

4

 

3

2

1

0

Byte

 

 

 

 

 

 

 

 

 

0

 

 

 

Page Code (3Ch)

 

 

 

1

 

 

 

 

Reserved

 

 

 

2

(MSB)

 

 

Page Length (n+1)

 

 

 

3

 

 

 

 

 

 

 

 

(LSB)

 

Bit

7

6

5

4

3

 

2

 

1

0

 

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

0

(MSB)

 

Parameter Code (0001h - 0012h and 0101h - 0112h)

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

(LSB)

 

2

DU (0)

DS (1)

TSD (0)

 

ET (0)

 

 

TMC (00)

 

LBIN (0)

LP (0)

 

3

 

 

 

 

Parameter

Length (n-3)

 

 

 

 

4

(MSB)

 

 

 

Parameter Value

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

(LSB)

Parameter Code:

 

 

 

 

 

 

 

 

 

 

 

Code

Description

Length

0001h

Current Groups Written

8

0002h

Current Rewritten Tracks

8

0003h

Current Groups Read

8

0004h

Current C3 ECC Count

8

0005h

Previous Groups Written

8

0006h

Previous Rewritten Tracks

8

0007h

Previous Groups Read

8

0008h

Previous C3 ECC Count

8

0009h

Total Groups Written

8

000Ah

Total Rewritten Tracks

8

000Bh

Total Groups Read

8

000Ch

Total C3 ECC Count

8

000Dh

Load Count

4

000Eh

Access Count

4

000Fh

Update Replace Count

8

0010h

Last Valid Absolute Frame Number

8

0011h

Partition Attribute

8

0012h

Maximum Absolute Frame Number

8

6-30