WMF Americas 1400 Appendix Technical Data, machine should be installed with clearance of not

Models: 1400

1 64
Download 64 pages 23.21 Kb
Page 59
Image 59
machine should be installed with clearance of not

 

Appendix: Technical Data

 

 

 

 

Mains voltage tolerance

230 V + 6 % - 10 %, mains outage < 50 ms no

 

interruption of function

 

 

Water supply

3/8 inch flexihose connector with mains tap and

(optional constant water

filter on customer supply side, water temperature

connection)

max. 35 °C.

 

min. 2 bar flow pressure ati 2 l/min., max. 6 bar

 

 

Water quality

For drinking water over 5° dCH (carbonate hard-

 

ness) a WMF anti-scale filter should be included.

 

 

Drain outlet

Flexihose to DN 19, min. gradient 2 cm/m

(optional)

 

 

 

Ambient temperature

+ 5°C to max. + 35°C

 

(Do not expose the coffee machine to frost).

Maximum humidity

80 % relative humidity without condensation,

 

no water spray, do not use unit outdoors!

Protection

IP X0

 

 

Inbuilt clearances

For operating, service and safety reasons the

 

machine should be installed with clearance of not

 

less than 50 mm at the back and sides from the

 

building or non-WMF components.

 

A clear height of 100 mm from the top of the sup-

 

porting surface should be ensured. Recommen-

 

ded height of the working surface is a minimum of

 

850 mm from floor level.

 

If the machine connections are to be routed down

 

through the counter, remember also to allow

 

space for the connections. These may restrict the

 

available space below the machine.

 

 

Anti-scale filter installed

490 mm (height) x 118,8 mm (diameter)

dimensions (03.9314.0001)

plus space requirement for the connection tubes

 

 

* The existing electricity supply must conform to the currently valid national rules (for Germany, VDE 0100).

To improve safety the coffee machine should be fitted with an FI 30 mA earth leakage current circuit breaker to EN 61008 standards. A plug top wall socket should be fitted near the machine. If the mains connection lead of this coffee machine is damaged it must be replaced by WMF Customer Services or a similarly qualified person.

If the coffee machine is permanently connected to the mains then an all-pole disconnecting separator (mains switch) to EN 60947 standards with a minimum 3 mm contact gap must be included. For flexible connection a separator switch is recommended.

Mains cable must not come into contact with hot surfaces.

Mains switch and plug top are part of the customer‘s on-site installation.

The machine may not have a fixed permanent mains connection if installed on any mobile furniture item.

User Manual WMF presto

59

 

Page 59
Image 59
WMF Americas 1400 user manual Appendix Technical Data, machine should be installed with clearance of not