![](/images/new-backgrounds/1061149/6114919x1.webp)
WOLF D OW N D R A F T VENTILATION SYSTEMS
D OW N D R A F T INSTALLATION | CON T R O L MODULE |
Set the downdraft into the opening. Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight. NOTE: The leveling brackets can be removed and reattached in other positions. The flange of the leveling bracket may have to face inward in tight cabinet installations. Refer to the illustration below.
Secure the downdraft to the countertop by holding the downdraft against the back of the countertop
Screw the leveling brackets to the bottom of the cabinet. Tighten the screws holding the leveling brackets to unit on each side.
To reduce the risk of burns or ignition of clothing by reaching across burners, control module must be mounted at least 76 mm from edge of cooktop
The
The control module can be located anywhere within reach of the 3 m power cable and a minimum of 76 mm from edge of cooktop
IMPORTANT NOTE: Do not place the module where it will be in the way of cooking, where hot pans may be placed or where hot liquids could be spilled on the controls.
mounting screws
leveling bracket – flange facing out
leveling bracket – flange facing in
Downdraft mounting brackets
10