ACCESSORIES
Optional acces- sories are available through your Wolf dealer. To obtain local dealer information, visit our website, wolfappliance.com.
WOLF D OW N D R A F T VENTILATION SYSTEMS
B LOW E R OPTIONS | D U C T I N G CONSIDERATIONS | |
Wolf downdraft Models ICBDD30I, ICBDD36I | IMPORTANT NOTE: Always consult a | |
and ICBDD45I include an 850 m3/hr internal | qualified HVAC Engineer for specific ducting | |
blower. Models ICBDD30R, ICBDD36R and | applications. | |
ICBDD45R are shipped without a blower | Wolf downdraft models with an internal blower | |
assembly and can be used with a 1529 m3/hr | ||
are designed for use with 83 mm x 254 mm | ||
remote blower (812307), available through | ||
ductwork and 83 mm x 356 mm ductwork for | ||
your Wolf dealer. | ||
models with a remote blower. Each can be | ||
| ||
IMPORTANT NOTE: Blower options vary with | transitioned to 203 mm or 254 mm round | |
the cooking surface. For recommendations, | ductwork. | |
refer to the Wolf Design Guide found on the | For best performance, 254 mm round ductwork | |
Wolf website, wolfappliance.com. | ||
is recommended. The downdraft will operate | ||
| ||
IMPORTANT NOTE: Install this downdraft | most efficiently when the ductwork does not | |
ventilation system only with a Wolf blower. | exceed 12 m in length. |
The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. A straight, short duct run with a limited number of elbows and transitions will allow the downdraft to perform most efficiently.
A
amount of blower noise, but will not eliminate the noise completely.
Choose the ducting option that allows the shortest length of ductwork and a minimum number of elbows and transitions. Check the location of floor joists, wall studs, electrical wiring or plumbing for possible interference with the ductwork. Refer to the illustrations below for ducting options.
WALL CAP |
305 mm |
MIN TO |
GROUND |
305 mm |
MIN TO |
GROUND |
REMOTE |
BLOWER |
254 mm |
ROUND |
305 mm |
MIN TO |
GROUND |
254 mm | REMOTE |
ROUND | BLOWER |
INTERNAL BLOWER | INTERNAL BLOWER | REMOTE BLOWER | |||
|
|
|
|
|
|
INSTALLATION | THROUGH WALL | INSTALLATION | THROUGH WALL | INSTALLATION THROUGH WALL | |
|
|
|
Downdraft ducting options
REMOTE BLOWER
ROOF MOUNT INSTALLATION
12