ACCESSORIES

Optional acces- sories are available through your Wolf dealer. To obtain local dealer information, visit our website, wolfappliance.com.

WOLF D OW N D R A F T VENTILATION SYSTEMS

B LOW E R OPTIONS

D U C T I N G CONSIDERATIONS

Wolf downdraft Models ICBDD30I, ICBDD36I

IMPORTANT NOTE: Always consult a

and ICBDD45I include an 850 m3/hr internal

qualified HVAC Engineer for specific ducting

blower. Models ICBDD30R, ICBDD36R and

applications.

ICBDD45R are shipped without a blower

Wolf downdraft models with an internal blower

assembly and can be used with a 1529 m3/hr

are designed for use with 83 mm x 254 mm

remote blower (812307), available through

ductwork and 83 mm x 356 mm ductwork for

your Wolf dealer.

models with a remote blower. Each can be

 

IMPORTANT NOTE: Blower options vary with

transitioned to 203 mm or 254 mm round

the cooking surface. For recommendations,

ductwork.

refer to the Wolf Design Guide found on the

For best performance, 254 mm round ductwork

Wolf website, wolfappliance.com.

is recommended. The downdraft will operate

 

IMPORTANT NOTE: Install this downdraft

most efficiently when the ductwork does not

ventilation system only with a Wolf blower.

exceed 12 m in length.

The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. A straight, short duct run with a limited number of elbows and transitions will allow the downdraft to perform most efficiently.

Aremote-mounted blower will minimize the

amount of blower noise, but will not eliminate the noise completely.

Choose the ducting option that allows the shortest length of ductwork and a minimum number of elbows and transitions. Check the location of floor joists, wall studs, electrical wiring or plumbing for possible interference with the ductwork. Refer to the illustrations below for ducting options.

WALL CAP

305 mm

MIN TO

GROUND

305 mm

MIN TO

GROUND

REMOTE

BLOWER

254 mm

ROUND

305 mm

MIN TO

GROUND

254 mm

REMOTE

ROUND

BLOWER

INTERNAL BLOWER

INTERNAL BLOWER

REMOTE BLOWER

 

 

 

 

 

 

INSTALLATION

THROUGH WALL

INSTALLATION

THROUGH WALL

INSTALLATION THROUGH WALL

 

 

 

Downdraft ducting options

REMOTE BLOWER

ROOF MOUNT INSTALLATION

12

Page 12