I N S TA L L AT I O N I N S T RU C T I O N S
O V E R A L L D I M E N S I O N S
MODELS ICBDD45I AND ICBDD45R
Overall Width | 1156 mm |
Width of Chimney | 1048 mm |
|
|
Overall Height (above countertop) | 230 mm |
|
|
Overall Depth | 60 mm |
|
|
Depth of Chimney | 38 mm |
|
|
Dimensions may vary to –+ 3 mm.
E L E C T R I C A L R E Q U I R E M E N T S
Wolf downdraft ventilation systems require a separate, 240 V 50/60 Hz power supply. The service should have its own 10A circuit breaker. The unit is supplied with a 2.5 m CEE 7/7 “Schuko” style Continental European power cord. The specific location of the outlet is not critical, as long as it is within reach of the power cord that is located
IMPORTANT NOTE: If Model ICBDD30 is to be installed in a 762 mm wide cabinet, Model ICBDD36 in a 914 mm wide cabinet or Model ICBDD45 in a 1156 mm wide cabinet, the electrical outlet cannot be located on the back wall of the cabinet. The outlet can be placed in an adjacent cabinet within reach of the power cord. An access hole for the power cord must be drilled in the cabinet wall.
Choose the electrical location shown in the illustration below that best suits your installation.
IMPORTANT NOTE
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
230 mm
1156 mm
1048 mm
38 mm
DEPTH OF
DOWNDRAFT CHIMNEY
60 mm
| E |
762 mm min | OPTIONAL |
ELECTRICAL | |
FOR MODEL ICBDD30 | LOCATION IN |
914 mm min | ADJACENT RIGHT |
FOR MODEL ICBDD36 | SIDE CABINET |
| |
1156 mm min |
|
FOR MODEL ICBDD45 |
|
Models ICBDD45I and ICBDD45R | Location of electrical |