Introduction

Introduction

Knockout panels for additional Bypass Switch Assembly for additional circuit breakers

The Sine Wave Plus Long AC Conduit Box (ACCB-L and ACCB-L-L1) connects to the AC side of a Sine Wave Plus inverter and accepts AC conduit runs. It is designed to protect the wiring connections to the inverter and provides room for up to nine additional AC disconnect breakers (Square D, Type QOU, DIN rail mounted) to protect user-specified loads.

There are three models of ACCB-L:

the ACCB-L Basic,

the ACCB-L-L1, and

the ACCB-L-L2.

The ACCB-L contains a ground bar only and provides no wiring.

The ACCB-L-L1 includes a ground wire attached to the ground bar, an AC bypass switch (for a single AC input source) and input/output wiring attached to the AC Input/output Terminals, a Neutral bar with neutral wire installed, and an isolated HOT bar.

The ACCB-L-L2 configuration is created by field-intalling an ACCB-L2-PCK into an ACCB-L-L1. The ACCB-L2-PCK consists of another field-installable AC Bypass Switch with wiring and an isolated AC Bus Bar.

This guide provides instructions for connecting the Long AC Conduit Box to the inverter and other system components (i.e., utility panel, AC distribution panel, grounding, and generator). It also provides instructions for installing additional Square D™, Type QOU, DIN rail-mounted circuit breakers.

ACCB-L includes:

 

 

A

Front Cover

 

 

B

Blockoff Plates

B

C

C

Ground Bar

A

D

Din Rail

 

 

 

Blockoff

D

 

 

Plates

 

 

 

 

 

B

 

 

 

Cover

Base

Figure 1-1The Sine Wave Plus ACCB-L Basic

1–2

973-0031-01-01 Rev A

Page 16
Image 16
Xantrex Technology ACCB-L-L1 manual Introduction, 1The Sine Wave Plus ACCB-L Basic