Wiring the Inverter
5.On the female terminal, connect the protective earth wire to the terminal marked with the ground ( ) symbol. See Figure
6.Connect the neutral wire to the terminal marked with 1.
7.Connect the Phase L wire to the terminal marked with 2. Terminal 3 is not used.
8.After ensuring all the wires are tightened in their terminals, screw the casing onto the female terminal.
9.Replace the remaining components of the female cable connector, ensuring a tight seal.
10.Tighten the pressing screw.
|
| Pinch ring |
ACconnector terminals | Shell | Seal |
| ||
|
| |
Female terminal |
| Pressing screw |
|
|
Outer ring
Notch
Figure
Phase L wire | Not used |
| Protective Earth |
Neutral wire | (ground) wire |
Figure
Connecting to the GT Inverter
To connect the AC connector to the GT Inverter:
1.Line up the notch on the female AC cable connector with the connector on the GT Inverter.
2.Insert the AC cable connector into the connector on the GT Inverter.
3.Secure the connector by turning the outer ring.