Monitoring the Inverter
Table
Display | Description |
|
|
System 2000W | Power being produced by the system now. |
Today 9.875kWh | Cumulative energy produced by the system today. |
|
|
If there is sufficient energy from the PV array, this screen is displayed continuously while the system is operating normally. In a multiple unit system connected by network cables, the power and cumulative energy values displayed are for the entire system.
During low light conditions when the GT Inverter cannot produce any power, the Normal Operation default screen flashes alternately (every two seconds) with the Insufficient Solar Energy screen (see Table
More screens for all | Besides the default normal operation display, more system information messages | |||||
systems | can be viewed. |
|
|
| ||
| To view more Normal Operation information: | |||||
| • Tap the Xantrex logo near the LCD to advance the display to the next screen. | |||||
| Normal operation screens shown in Table | |||||
| as you tap successively on the unit. They are common to all GT Inverter | |||||
| systems, no matter how many units are installed. | |||||
| If you continue to tap the unit, then the LCD continues to cycle through all of the | |||||
| available normal operation screens. Each screen is displayed for a maximum of | |||||
| 30 seconds. If you do not tap again during that time period, then the LCD | |||||
| backlight turns off and the display reverts to the default system message screen. | |||||
| Table | Normal Operation Screens for All GT Inverters | ||||
| Tap |
| Display* |
| Description | |
|
|
| ||||
|
|
|
|
|
| |
| 1st time |
| System 2000W |
| LCD backlight turns on for better readability | |
|
|
| Today 2.500kWh |
| and default Normal Operation screen is | |
|
|
|
|
|
| displayed. |
|
|
|
|
|
| |
| 2nd time |
| System Lifetime |
| Lifetime energy produced by the GT Inverter | |
|
|
| 305kWh |
| system. | |
|
|
|
|
|
| |
| 3rd time |
| Time Online |
| Length of time inverter has been online today, in | |
|
|
| Today hh:mm:ss |
| hours (hh), minutes (mm) and seconds (ss). | |
|
|
|
|
|
| |
| 4th time |
| Array Readings |
| Immediate DC voltage and current readings | |
|
|
| 350.5V | 8.4A |
| from the PV array. |
|
|
|
|
|
| |
| 5th time |
| Grid Readings |
| Immediate AC voltage and frequency readings | |
|
|
| 242.6V | 60.0Hz |
| from the Grid. |
|
|
|
|
|
|
|