Mounting the Inverter
WARNING: Shock hazard
Before drilling holes to mount the GT Inverter, ensure there are no electrical wires or plumbing in this area.
WARNING: Personal injury
The GT Inverter weighs approximately 19 kg (41 lb). Always use proper lifting techniques during installation to prevent personal injury.
WARNING: Explosion hazard
Do not store combustible or flammable materials anywhere near the inverter.
Surfaces for Mounting
| The GT Inverter weighs approximately 19 kg (41 lb). The supporting surface must |
| be strong enough to handle 75 kg (160 lb). If the supporting surface is not strong |
| enough to handle that weight, then supporting material such as a sheet of plywood |
| can be used to enhance the strength of the mounting surface. |
| The GT Inverter can be mounted to a vertical surface such as wallboard, wood |
| siding, concrete wall or pole assembly. |
Mounting on poles | • See “Mounting on Poles or Rails” on page |
or rails | is a minimum of 100 cm (39 inches) from the ground if mounted outdoors. |
Mounting to | • Installation onto wallboard requires either the use of a supporting material |
wallboard with | such as plywood or securing the mounting screws to supporting wall studs. |
support | Use at least two screws and anchors to secure the unit to the supporting |
| material. |
Mounting to siding | • If mounting to exterior siding using a wall stud for support, the plywood |
using wall studs | backing will not be needed. Use at least two lag screws to secure the unit to |
| the supporting material. Ensure the screws enter the stud at least 4 cm |
| (1.5 inches) to adequately support the weight of the unit. After securing the |
| bracket, the screws or bolts and washers should protrude no more than 6 mm |
| (1/4 inch) from the bracket surface. |
Mounting to | • If mounting the unit on a concrete surface using anchors with no supporting |
concrete surface | material, use four screws and anchors, instead of two, to adequately secure the |
| unit and distribute the weight. |
|
|
| Important: Other than the mounting bracket, no mounting hardware is supplied with |
| the GT Inverter. It is recommended to use 6 mm (1/4 inch) diameter fasteners. However, |
| because mounting surfaces can vary, installers must select appropriate hardware for each |
| installation. |
|
|
| Important: Local codes may impose additional mounting requirements in earthquake |
| or other |
|
|