Monitoring the Inverter
Additional Fault | Additional message screens can be viewed in fault mode by tapping the Xantrex | |||||
messages for all | logo near the LCD. Each additional tap displays the next screen in the order | |||||
systems |
|
|
| |||
| Table | Additional Fault Mode Screens | ||||
| Tap |
| Display* |
| Description | |
|
|
| ||||
|
|
|
|
|
| |
| 1st time |
| Current fault message |
| LCD backlight turns on for better readability. | |
|
|
|
|
| ||
|
|
|
|
|
| |
| 2nd time |
| System 0W |
| Energy being produced by the system now. | |
|
|
| Today 2.500kWh |
| Cumulative energy produced by the system | |
|
|
|
|
|
| today. |
|
|
|
|
|
| |
| 3rd time |
| System Lifetime |
| Lifetime energy produced by the GT Inverter | |
|
|
| 305kWh |
| system. | |
|
|
|
|
|
| |
| 4th time |
| Time Online |
| Length of time inverter was online today, in | |
|
|
| Today hh:mm:ss |
| hours (hh), minutes (mm) and seconds (ss). | |
|
|
|
|
|
| |
| 5th time |
| Array Readings |
| Immediate DC voltage and current readings of | |
|
|
| 350.5V | 8.4A |
| power from the PV array. |
|
|
|
|
|
| |
| 6th time |
| Grid Readings |
| Immediate AC voltage and frequency readings | |
|
|
| 242.6V | 60.0Hz |
| of power from the Grid. |
|
|
|
|
|
|
|
*In a multiple unit system with network cables properly installed, the system values displayed are for the entire system. Time online and array readings are for the local inverter and PV array associated with that inverter.
Special ScreensSpecial message screens are displayed in specific situations that are not considered fault situations. They can appear in any mode of operation. These screens are described in Table
Table
Display | Description |
Reconnecting in Time remaining in seconds (sss) before the GT Inverter
sssseconds reconnects to the Grid. This is a protection timer that runs at startup and after any Grid fault.
Inverter GT Inverter switching (or has switched) from Normal
Offline Operation to Offline mode. This screen may flash alternately with a Fault message screen.