Configuration
324 975-0125-02-01
Eqz Volts
Full name Equalization voltage
Configurable setting This setting lets you set the desired equalization voltage. This menu is displayed
only if charger equalization is enabled on the house battery bank. Select a setting
based on the battery manufacturers recommendation. For more information, see
Battery Charging Reference for the Main Charger on pageB1.
Force Charge
Full name Force Charge
Configurable setting This setting forces the main charger to be enabled (On) whenever you have
qualified AC or reacquired qualified AC. If Force Enabled is not on, you must
turn it to On using the System Control Panel.
When to use If you want the main charger to automatically start when you connect to qualified
AC input.
Outcome The main charge r starts whenever qualifie d AC input appears.
Eqz Volts [15.5V]
Range of values Increment Default
13.5 to 15.5 VDC 0.1 volts 15.5 VDC
Important:
The Echo Charger i s not affected by this setting.
Force Charge [On]
Values D efau lt
On On
Off