Configuration
975-0125-02-01 323
Sense Interval
Configurable setting This setting lets you adjust the interval of load sensing. The longer the interval,
the more power you will save. However, the longer intervals may cause delays in
the inverter power up and starting your loads.
Cfg AC Limits (Configure AC Limits)
Cfg AC Limits is a sub-menu. If selected, a list of sub-menu items appear. For
more information on this sub menu, Configure AC Limits, see page3 25.
# Chg Stages
Full name Number of charge stages
Configurable setting These settings let you adjust the charger stages of your house battery bank to
either two-stage charging or three-stage chargin g. Se e Battery Charging
Reference for the Main Charger on page B1 for an explanation of two-stage and
three-stage charging.
Sense Interval [1s]
Range of values Increment Default
1 second to 25
seconds 1 second 1 second
# Chg Stages [3Stage]
Value Default
2StgNoFloat
3Stage 3Stage
Important:
The Echo Charger i s not affected by this setting.