Configuration
975-0125-02-01 311
Charger
Configurable setting This setting lets you enable or disable the oper ation of the main char ger. When the
main charger is enabled and AC is connected to the input, the house battery bank
will charge. The Echo Charger will charge if it is enabled separately in the Echo
Charger menu. See Echo Chg on page318.
The Disabled setting of this item will disable the main cha rg er and c an be disa bled
at any time during the charge cycle.
If the charger is enabled and the AC is not qualified as good, then the charger wil l
not operate until AC qualifies as good.
The charger can be enabled or disabled from the front panel of the MS2000 or
from the System Control Panel (SCP). In the example shown, the charger is
enabled.
Outcome Use the default Enabled setting to ensure batteries are always being charged when
connected to an AC source. Disabling the charger w ill turn off the charg e
function. Then the next time qualified AC power is connected, the charger is
automatically enabled and charging will begin, if Force Charge is enabled. If
Force Charge is not enabled, charging will not occur until the Charger setting is
changed from disabled to enabled.
See Force Charge on page 324 for more information on this feature.
Important:
Both the main charger and the Echo Charger mus t be set to enabled for the
Echo Charger to operate.
Charger [Enabled]
Value Default
Enabled Enabled
Disabled