Operation
975-0125-02-01 23
Using the System Control Panel
The System Control Panel has important fe atures which youll want to be familiar
with, as shown in Figure 2-1.
Display screen System information is shown on the display screen with an adjustable backlight.
Indicator lights Four indicat or lights on the front panel indi cate the oper ating sta tus of the Xanbus
system.
Push buttons Four push buttons allow you to select device menus and change or display
settings. The red System button toggles the System Control Panel and Xanbus-
enabled devices between Operate mode and Power Save mode. For more
information on the different system modes, see System Modes on page26.
Figure 2-1
System Control Panel
Table 2-1
System Control Panel Features and Buttons
Feature Description
1AC In/Charge light indicates that qualified AC is presen t at
the input of the inverter/charger. When the MS2000 is
connected to a qualified AC source like the utility grid or a
generator, this light on the System Control Panel illuminates.
2Inverter On light illuminates when the MS2000 is enabled
(turned on).
3Low Battery light illuminates when the house batt ery voltage
on the MS2000 is low.
4Fault light indicates a condition that requires use r attention
and intervention. The Fault light illuminates when any
Xanbus-enabled device connected to the network is in fault.
See Faults and Warnings on page42 for the definitions of a
fault and warning.
5Enter button
Confirms selection of a menu item.
Moves you to the next screen.
9
10
567
8
1
2
3
4
1