Configuration
975-0125-02-01 315
Batt Type
Full name Battery Type
Configurable setting Select the type of battery for your house battery from Flooded, AGM, Gel or
Custom. If a battery temperature sensor is not present, the MS2000 uses cold,
warm or hot settings with the hot setting as the default.
When to use This setting is adjusted for the type of house battery you have. It is important
during configuration to choose the correct setting (battery type) to optimize the
charge algorithm for your battery and to properly enable or disable equalization.
See Battery Charging Reference for the Mai n Ch arge r on page B1 for more
information.
The custom setting is selected to get the battery settings programmed by the
dealer.
Batt Size
Full name Battery size
Configurable setting This feature lets you select the size of the house battery bank.
When to use Adjust this setting to match the amp-hour capacity of the house battery bank.
Outcome Reduces the main charger out p ut curr ent to protec t against charging smaller
battery banks too aggressively. This setting char ges batteries appropriately based
on the amp-hour capacity of the house battery bank.
The Echo Charger is optimized to produce a maximum 10 amps DC output and is
not affected by this setting. See Battery Charging Reference for the Main
Charger on page B1 for more in formation.
Batt Type [Flooded]
Value D efault Battery
Type
Flooded Flooded
Custom
AGM
Gel
Important:
The Echo Charger i s not affected by this setting.
Batt Size [440 Ah]
Range of values Increment Default
50 Ah to 2000 Ah 10 Ah 440 Ah