Table 1.4Specifications for XFR 2800 W Series Supply with RS-232 Interface Installed (60 V to 600 V)
Models 60-46 100-28 150-18 300-9 600-4
Program Resolution
Voltage
Current
OVP
9.3mV
1.4mA
9.3mV
15.5mV
0.9mA
15.5mV
23.2mV
0.6mA
23.2mV
46.4mV
0.3mA
46.4mV
92.7mV
0.2mA
92.7mV
Program Accuracy1
Voltage
Current
OVP
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-130 power supply to 10 volts.
The expected result will be within the range of 10volts ± 75mV ± 0.12% of the set voltage of 10 volts
150mV
±0.3%
80mA
±0.1%
600mV
150mV
±0.35%
80mA
±0.1%
1.0V
225mV
±0.35%
80mA
±0.1%
1.5V
225mV
±0.35%
75mA
±0.1%
3.0V
300mV
±0.35%
75mA
±0.1%
6V
Readback Resolution
Voltage
Current
9.3mV
1.4mA
15.5mV
0.9mA
23.2mV
0.6mA
46.4mV
0.3mA
92.7mV
0.2mA
Readback Accuracy1
Voltage
Current
150mV
±0.3%
80mA
±0.1%
150mV
±0.35%
80mA
±0.1%
225mV
±0.35%
80mA
±0.1%
225mV
±0.35%
75mA
±0.1%
300mV
±0.35%
75mA
±0.1%