Features and Specifications

Specifications

Table 1.4 Specifications for XFR 2800 W Series Supply with RS-232 Interface Installed (60 V to 600 V)

Models

60-46

100-28

150-18

300-9

600-4

Program Resolution

9.3mV

15.5mV

23.2mV

46.4mV

92.7mV

Voltage

Current

1.4mA

0.9mA

0.6mA

0.3mA

0.2mA

OVP

9.3mV

15.5mV

23.2mV

46.4mV

92.7mV

Program Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

300mV

 

±0.3%

±0.35%

±0.35%

±0.35%

±0.35%

Current

80mA

80mA

80mA

75mA

75mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

OVP

600mV

1.0V

1.5V

3.0V

6V

Readback Resolution

 

 

 

 

 

Voltage

9.3mV

15.5mV

23.2mV

46.4mV

92.7mV

Current

1.4mA

0.9mA

0.6mA

0.3mA

0.2mA

Readback Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

300mV

 

±0.3%

±0.35%

±0.35%

±0.35%

±0.35%

Current

80mA

80mA

80mA

75mA

75mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-130 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts

16