Installation and Configuration

Initial Inspection

 

JUMPER SELECTION

J65

Local OVP control selection

[closed] [default]. See page 32.

 

 

[open] Front Panel OVP Control.

J93

User TTL shutdown (S/D)

[1-2] User TTL S/D line active low. See page 35.

 

selection

[2-3] [default] User TTL S/D line active high.

J103

Remote OVP Control Selection

[closed] [default]. See page 32.

 

 

[open]

J216

RS-232 (J5) transmit and

[3-1]

Receives on pin 3 (TXD) [default]

 

receive pin selection

[4-6]

Transmits on pin 2 (RXD) [default]

 

 

[3-5]

Receive on pin 2

 

 

[4-2]

Transmit on pin 3

J217 RS-232 flow control selection of RTS/CTS (ready to send/clear to send) or DTR/DSR (data terminal ready/data set ready)

J218 RS-232 flow control selection of RTS/CTS or DTR/DSR

[1-3][4-6] [default] RTS input on pin 7 (used with CTS output on pin 8)

[3-5][4-6] DTR input on pin 4 (used with DSR output on pin 6)

[2-4][[3-5] [default] CTS output on pin 8 (used with RTS input on pin 7)

[2-4][1-3] DSR output on pin 6 (used with DTR input on pin 4)

Note: All other jumpers are not user-selectable.

 

 

LED INDICATORS

CR89

Red Diagnostic LED

Bus error or soft restart on Slave circuitry.

CR166

Red Diagnostic LED

Soft restart on Master circuitry.

CR167

Green Diagnostic LED

Bus error on Master circuitry.

 

 

EPROMS

U117

Slave EPROM

See revision number stamped on EPROM.

U191

Master EPROM

See revision number stamped on EPROM.

Figure 2.3 RS-232 Interface PCB

22

Operating Manual for RS-232 for XHR/XFR Series Power Supply

Page 24
Image 24
Xantrex Technology RS232-XHR manual RS-232 Interface PCB