Features and Specifications

Specifications

Table 1.5 Specifications for XHR 1000 W Series Supply with RS-232 Interface Installed (7.5 V to 60 V)

Models

7.5-130

20-50

33-33

40-25

60-18

Program Resolution

1.2mV

3.1mV

5.1mV

6.2mV

9.3mV

Voltage

Current

18.3mA

7.1mA

4.7mA

3.6mA

2.6mA

OVP

1.2mV

3.1mV

5.1mV

6.2mV

9.3mV

Program Accuracy1

 

 

 

 

 

Voltage

10mV

75mV

75mV

75mV

150mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.25%

Current

500mA

250mA

165mA

140mA

120mA

 

±0.1%

±0.1%

±0.1%

±0.15%

±0.1%

OVP

80mV

200mV

330mV

400mV

600mV

Readback Resolution

 

 

 

 

 

Voltage

1.2mV

3.1mV

5.1mV

6.2mV

9.3mV

Current

18.3mA

7.1mA

4.7mA

3.6mA

2.6mA

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

75mV

75mV

75mV

150mV

 

±0.12%

±0.12%

±0.2%

±0.3%

±0.25%

Current

500mA

250mA

165mA

140mA

120mA

 

±0.1%

±0.1%

±0.15%

±0.15%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-50 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.

Release 3.1

17

Page 19
Image 19