Operation

Command Summary

Table 3.4

Query Commands

Command

Description

 

 

AUXA?

Asks for the state of the set value for the AUXA command

 

 

AUXB?

Asks for the state of the set value for the AUXB command

 

 

CMODE?

Asks for the power supply’s calibration mode status.

 

 

DLY?

Asks for the programmable time delay setting before the supply

 

reports fault conditions.

 

 

ERR?

Asks for the most recent remote programming error which occurred in

 

the supply since the last time the error query command (ERR?) was

 

used.

 

 

FOLD?

Asks for the supply’s present foldback setting.

 

 

HOLD?

Asks for the present hold mode setting.

 

 

ID?

Asks for the power supply’s model name and master EPROM version.

 

 

IMAX?

Asks for the supply’s soft current limit setting.

 

 

IOUT?

Measures the supply’s actual current output.

 

 

ISET?

Asks for the supply’s present output current limit setting.

 

 

OUT?

Asks for the present enabled/disabled status of the supply’s output.

 

 

OVSET?

Asks for the supply’s present over voltage protection limit.

 

 

REN?

Asks for the state of remote enable.

 

 

ROM?

Asks for the version number of the master and slave EPROMs on the

 

interface PCB.

VMAX?

Asks for the supply’s soft voltage limit setting.

 

 

VOUT?

Measures the supply’s actual voltage output.

 

 

VSET?

Asks for the supply’s present output voltage setting.

 

 

42

Operating Manual for RS-232 for XHR/XFR Series Power Supply

Page 44
Image 44
Xantrex Technology RS232-XHR manual Auxa?