Installation and Configuration
Local
Lockout
(LLO)
Command
Use the Local Lockout command to disable the LOCAL button on the power supply front panel. With LLO in effect, you cannot return to local control by pressing the front panel LOCAL switch. You can still return to local mode by sending the Go to Local (GTL) command. To turn off LLO and return the power supply to local mode, send the REN OFF command. Only the REN OFF command will remove the LLO condition.
Example:
| LLO | Set Local Lockout | 
| GTL | Return the power supply to local mode. Local | 
| 
 | Lockout is still in effect | 
| REN OFF | Turn off Local Lockout and return the power | 
| 
 | supply to local mode | 
RS-232  Connection
WARNING
Do not operate the power supply and the computer at significantly different frame potentials. The interface connection system may not be capable of handling the resulting excessive ground currents.
Use an approved 
Figure 2.4 RS-232  Connector (J5) Pinouts (default configuration)
| 30 | Operating Manual for  | 