Installation Planning

Locating the Sun Tie XR

The Sun Tie XR should be installed in locations that meet the following requirements:

Vertical

The UL listing for the Sun Tie XR requires it

 

to be mounted vertically.

Dry

When the Sun Tie is mounted outdoors, attach

 

the optional Rain Shield (STRS) to prevent

 

water entering the unit.

Temperature

The unit meets specifications from 32 to

 

113 °F (0 to 45 °C) but will operate within the

 

temperature extremes of most climates—from

 

-38 to 113 °F (-39 to 45 °C). At extreme cold

 

temperatures the LCD display may not

 

function normally and it is recommended that

 

an indoor-mounted Remote Monitor be used.

 

At temperatures above 45 °C, the unit begins

 

derating power. See “Temperature Derating

 

Curve” on page A–6.

Ground clearance

The Sun Tie requires at least 36 inches (100

 

cm) of clearance between the bottom of the

 

unit and the ground.

Dust free

Dust can be drawn inside and accumulate

 

within the unit, interfering with wiring

 

connections and ventilation.

WARNING: SHOCK HAZARD

Do not install the Sun Tie XR unit outdoors without the Rain Shield. Water entering the unit could cause a dangerous condition and cause the unit to fail. Failure due to improper installation will void the warranty.

Routing the wires

Typical

Determine all wire routes to and from the Sun Tie XR. Typical routing

configurations

configurations include:

 

• AC wiring from the Sun Tie XR to the main service panel

 

DC input wiring from the PV array to the Sun Tie XR

 

DC ground from the PV array to an external ground rod

975-0053-01-01

2–3