| Startup Procedure | |
After startup | After the | |||
| Sun Tie will display four messages that repeat every minute. | |||
|
| Display |
|
|
|
|
|
| |
| Message (with | duration |
|
|
| sample data) | (seconds) | Description | |
|
|
|
|
|
| 54 mppt 74 vdc | 0 – 8 | Message 1 shows the inverter’s | |
| 2500 W 12123 Wh* |
| DC regulation voltage for | |
|
|
| maximum power production, | |
|
|
| DC input voltage, power output, | |
|
|
| and energy harvested today. | |
|
|
|
|
|
| 244 vac 74 vdc | 8 – 16 | Message 2 shows AC input | |
| 2500 W 12123 Wh* |
| voltage, DC input voltage, the | |
|
|
| power output and energy | |
|
|
| harvested today. | |
|
|
|
|
|
|
| 16 – 24 | Repeats message 1. | |
|
|
|
|
|
|
| 24 – 28 | Repeats message 2. | |
|
|
|
|
|
| Lifetime Energy | 28 – 32 | Message 3 shows the amount of | |
| 10.000kWh |
| energy produced since | |
|
|
| installation and startup. | |
|
|
|
|
|
|
| 32 – 40 | Repeats message 1. | |
|
|
|
|
|
|
| 40 – 48 | Repeats message 2. | |
|
|
|
|
|
|
| 48 – 56 | Repeats message 1. | |
|
|
|
|
|
| Time Online | 56 – 60 | Message 4 shows how long the | |
| Today 00:00:00 |
| Sun Tie has been online since it | |
|
|
| last started. | |
|
|
|
|
|
*If the inverter is disconnected due to a line condition, this display will show one of the following messages:
•AC NOT PRESENT
•AC MAINS LOW
•AC MAINS HIGH
•FREQUENCY FAULT
Status Indicator LightsThe Sun Tie XR is equipped with two status indicator lights (LEDs) above the circuit breakers inside the wiring compartment. These light during operation to indicate the inverter’s current status. For information about reading these lights, see Chapter 4, “Troubleshooting”.