Startup Procedure

After startup

After the 300-second countdown timer and during normal operation, the

 

Sun Tie will display four messages that repeat every minute.

 

 

Display

 

 

 

 

 

 

 

Message (withduration

 

 

 

sample data)(seconds)Description

 

 

 

 

 

 

54 mppt 74 vdc

0 – 8

Message 1 shows the inverter’s

 

2500 W 12123 Wh*

 

DC regulation voltage for

 

 

 

maximum power production,

 

 

 

DC input voltage, power output,

 

 

 

and energy harvested today.

 

 

 

 

 

 

244 vac 74 vdc

8 – 16

Message 2 shows AC input

 

2500 W 12123 Wh*

 

voltage, DC input voltage, the

 

 

 

power output and energy

 

 

 

harvested today.

 

 

 

 

 

 

 

16 – 24

Repeats message 1.

 

 

 

 

 

 

 

24 – 28

Repeats message 2.

 

 

 

 

 

 

Lifetime Energy

28 – 32

Message 3 shows the amount of

 

10.000kWh

 

energy produced since

 

 

 

installation and startup.

 

 

 

 

 

 

 

32 – 40

Repeats message 1.

 

 

 

 

 

 

 

40 – 48

Repeats message 2.

 

 

 

 

 

 

 

48 – 56

Repeats message 1.

 

 

 

 

 

 

Time Online

56 – 60

Message 4 shows how long the

 

Today 00:00:00

 

Sun Tie has been online since it

 

 

 

last started.

 

 

 

 

 

*If the inverter is disconnected due to a line condition, this display will show one of the following messages:

AC NOT PRESENT

AC MAINS LOW

AC MAINS HIGH

FREQUENCY FAULT

Status Indicator Lights

The Sun Tie XR is equipped with two status indicator lights (LEDs) above the circuit breakers inside the wiring compartment. These light during operation to indicate the inverter’s current status. For information about reading these lights, see Chapter 4, “Troubleshooting”.