16 Analog I/O & Digital I/O
01V96i—Reference Manual
Setting the Transfer Format for Higher Sampling Rates
To operate the 01V96i at higher sampling frequencies
(88.2kHz or 96 kHz) and transfer digital audio signals to and
from connected external devices, you must set the data trans-
fer format in accordance with the sampling frequencies sup-
ported by the external devices.
1. Press the DISPLAY ACCESS [DIO/SETUP] but-

ton repeatedly until the DIO/Setup | Word

Clock page appears.

2. Select INT88.2k or INT96k as the wordclock

source.

3. Press the DISPLAY ACCESS [DIO/SETUP] but-

ton repeatedly until the DIO/Setup | Format

page appears.
4. Use the cursor buttons to move the cursor to

an IN/OUT parameter field (1), then rotate

the Parameter wheel or press the [INC]/[DEC]

buttons to set the data transfer format.

The IN/OUT parameters are used to set one of the follow-
ing data transfer formats for each slot input and output.
DOUBLE CHANNEL
In Double Channel mode, digital audio data is received
and transmitted as mono signals at a sampling rate that is
exactly half (44.1/48kHz) the current higher sampling
rate. Data is handled by two channels. This is useful when
you want to transfer data between the 01V96i operating at
a higher sampling rate and an external digital device that
supports 44.1/48 kHz.
•DOUBLE SPEED
In Double Speed mode, digital audio data is received and
transmitted at the current high sampling rate (i.e.,
88.2kHz or 96 kHz). Sele ct this mode if the devices that
support the higher sampling rates transmit or receive
data.
•SINGLE
In Single mode, digital audio data is received and trans-
mitted at a sampling rate that is half (44.1/48kHz) the
current higher sampling rate of the 01V96i. For example,
this is useful when you want to receive 44.1kHz digital
signals from an external digital device while the 01V96i is
operating at 88.2 kHz.
Note: When the 01V96i operates at a high sampling rate
(88.2kHz or 96 kHz), only two internal effects processors are
available.
Note: Double Channel mode reduces the total number of
inputs or outputs on the corresponding slot. The even-num-
bered channels are disabled.
1
Note: You can select this setting only for slots in which a dig-
ital I/O card that inputs/outputs double-speed digital audio
data (e.g., MY8-AE96, MY8-AE96S) is installed.
Note: You cannot select this setting for slots in which a digital
I/O card that inputs/outputs double-speed digital audio data
(e.g., MY8-AE96, MY8-AE96S) is installed.
Tip: The parameter fields display “–” if the slot contains no
I/O ca rd o r if an AD/ DA car d or oth er I/ O ca rd t hat do es n ot
allow you to set the transfer format has been installed.