62 Grouping Channels & Linking Parameters
01V96i—Reference Manual
Using Mute Group Master
In addition to the Mute Group function that links the opera-
tion of channel [ON] buttons, the 01V96i features a Mute
Group Master function that enables you to mute grouped
channels using the Master Mute buttons in a manner similar
to using a mute group on an analog mixing console. While
this function is enabled, the [ON] buttons for grouped chan-
nels will not be linked.
1. After you perform Step 5 in “Using Fader
Groups and Mute Groups” on page 59, use
the cursor buttons to select the INPUT MUTE
MASTER check box or OUTPUT MUTE MAS-
TER check box, then press [ENTER] to turn on
the Mute Group Master function.
2. When the Mute Master check box is checked,
use the group MASTER MUTE buttons to
mute or unmute the groups.
If channels are muted via the Mute Master function, the
channel [ON] button indicators flash. It is useful if you
assign the MASTER MUTE buttons to USER DEFINED
KEYS buttons.
Linking EQ and Compressor Parameters
Follow the steps below to link EQ or compressor parameters
for Input Channels or Output Channels. This function
enables you to set EQ or compressor parameters for multiple
channels to the same values simultaneously.
1. Press the DISPLAY ACCESS [PAIR/GROUP]
button repeatedly until one of the following
pages appears.
•In EQ page
This page enables you to set EQ links (a–d) for Input
Channels 1–32 and ST IN Channels 1–4.
•Out EQ page
This page enables you to set EQ links (e–h) for Bus Outs
(1–8), Aux Outs (1–8) and Stereo Out.