1 2 3 4 5 6 7 8 9 Automatic speaker setup

Warning messages

If a warning message is displayed after the measurement, you can still save the measurement results by following on-screen instructions. However, we recommend you perform YPAO again in order to use the unit with the optimal speaker settings.

Warning message

Cause

Remedy

 

 

 

 

 

Select “Wiring” in “Result” (p.56) and check the cable connections (+/-) of the speaker identified by

W-1: Out of Phase

A speaker cable may be connected with the reverse polarity

“Reverse”. If the speaker is connected incorrectly, turn off the unit and then reconnect the speaker cable.

(+/-).

Depending on the type of speakers or room environment, this message may appear even if the speakers are

 

 

 

connected correctly. In this case, you can ignore the message.

 

 

 

W-2: Over Distance

A speaker is placed more than 24 m (80 ft) from the listening

Select “Distance” in “Result” (p.56) and move the speaker identified by “>24.00m (>80.0ft)” within 24 m (80

position.

ft) of the listening position.

 

 

 

 

 

There are significant volume differences between the

Check the usage environment and cable connections (+/-) of each speaker, and the volume of the

W-3: Level Error

subwoofer. We recommend using the same speakers or speakers with specifications that are as similar as

speakers.

 

possible.

 

 

 

 

 

PREPARATIONS Optimizing the speaker settings automatically (YPAO)

En 59