Note
•The CRW3200E drive is set at slave by default. If you connect the drive as the sole secondary master, set the drive to master.
•If you connect an IDE device solely to an IDE cable, set the device to master and connect the drive to the end of the cable.
•If you start up the operating system from a SCSI hard drive, etc., there may be no IDE device connected to the primary. In such a case, Yamaha recommends that the CRW3200E drive be connected as the primary master.
•You may find that the IDE cable has one connector when you try to connect the removed device to another connector. In such a case, you are required to prepare an IDE cable with two connectors.
•You may have to change the master/slave setting to connect the removed device to another connector. For more details, refer to the documentation that comes with the device or refer to the manufacturer’s website.
E-IDE
Two IDE devices connected by one IDE cable are called “master” and “slave.”
Motherboard Primary | Master | Master |
Secondary Slave Slave
Continued on next page
12